PRODUCTS |
|
Mini-Z
- Zero Sequence Harmonic Filters
|
|
DESCRIPTION
Mini-Z
Zero
Sequence Harmonic Filters provide the best possible solution
to the system performance and power quality problems that
result from non-linear, load-generated zero sequence
harmonic currents. In addition, their application reduces
capital costs, system penalty losses and power costs. |
 |
|
Mini-Z Zero Sequence Harmonic Filters are connected at the load-end of three-phase, four-wire 'shared neutral' or three-phase, six-wire branch circuits. In 'landscaped' office environments, filters may be conveniently connected to pre-wired partitions via the partition manufacturer's standard wire-way connection cable. Where the partitions are not pre-wired or in private office areas, filters may be connected at branch circuits' 'home run' junction boxes. In computer room or audio/video editing and broadcast studio environments, 19 inch 'rack mount' filters may be used as the branch circuits' 'home run' junction boxes.
The application of filters in new distribution systems eliminates the need to oversize 'shared neutral' conductors or install separate neutral conductors for each phase in a branch circuit. Similarly, the application of filters in existing systems eliminates the need to replace branch circuits with undersized 'shared neutrals'. In either case, filters will eliminate the need to de-rate circuits, panels and switchboards. The de-rating of conventional distribution transformers can be reduced from approximately 45% to less than 15%. As a result, filters significantly reduce capital costs and power costs while providing significant performance and power quality improvements. |
|
|
|
TECHNICAL SPECIFICATION
Mini-Z
Zero Sequence Harmonic Filters are patented three-phase,
four/six-wire, copper-wound, common-core autotransformers. With less
than 0.9% zero sequence impedance and less than 0.3% reactance,
these filters provide a parallel (shunt) paths, with ultra-low zero
sequence impedance, for all single-phase load-generated zero
sequence harmonic currents.
Mini-Z

|
|
I0Filter
- Zero Sequence Harmonic Filters
|
|
DESCRIPTION
I0Filter
Zero
Sequence Harmonic Filters are innovative, high quality
three-phase, four-wire, passive electromagnetic devices. These
devices have been specifically designed to provide an
ultra-low zero sequence impedance parallel (shunt) path for
the removal of all zero sequence harmonic currents, regardless
of their frequency, from the upstream system. |

|
|
I 0Filter
performance
is optimized when they are installed as close as possible to
the phase-neutral connected non-linear loads. This is
typically accomplished by connecting the Filter at a
three-phase, four wire panel that supplies the single-phase
non-linear loads.
Directional
I0Filter
filters are
also available when treatment of only one of several
distribution panels in a sub-system is required
and/or mitigation of
positive and negative harmonic currents is also required. Any
of these filters can be used in combination in order to
provide the most effective and economical solution.
The application of
I0Filter
filters in
new distribution systems eliminates the need to oversize
neutral conductors in feeder circuits. Similarly, the
application of filters in existing systems eliminates the need
to replace undersized neutral conductors. In either case,
filters will eliminate the need to de-rate feeder circuits and
upstream switchboards. The de-rating of conventional
distribution transformers can be reduced from approximately
45% to less than 15%. As a result, filters significantly
reduce capital costs and power costs while providing
significant performance and power quality benefits. |
|
|
|
TECHNICAL SPECIFICATION
I 0Filter
Zero Sequence
Harmonic Filters are proprietary three-phase, four-wire, copper-wound,
common-core autotransformers. With less than 0.9% zero sequence
impedance and less than 0.3% reactance, these filters provide a
parallel (shunt) paths, with ultra-low zero sequence impedance, for
all single-phase load-generated zero sequence harmonic currents.
I0Filter
 |
|
Distribution
TransFilter
- Harmonic Filtering Transformer
|
|
DESCRIPTION
Distribution TransFilter
Harmonic
Mitigating Transformers are Ultra-High Efficiency
three-phase distribution transformers that have been
specially designed to mitigate the power quality problems
associated with non-linear, load-generated harmonic currents
in three-phase electrical distribution systems.
|
 |
|
K-Rated or
de-rated Transformers are only intended to survive in a
harmonic environment. By contrast,
Distribution
TransFilters
will
cancel zero sequence harmonic fluxes within the three-phase
magnetic core. In addition, positive and negative sequence
harmonic currents will cancel on their primary bus or within
their dual output secondary windings. |
|
|
|
TECHNICAL SPECIFICATION
Distribution
TransFilter Harmonic Filtering Transformers
are proprietary three-phase, four-wire, copper-wound, common-core
isolation transformers. Type 'DV' transformers, with less than 0.9%
zero sequence impedance and less than 0.3% reactance, provide a
parallel (shunt) paths, with ultra-low zero sequence impedance, for
all single-phase load-generated zero sequence harmonic currents.
Distribution
TransFilter
 |
|
Drive
TransFilter
- Harmonic Mitigating Drive Transformer
|
|
DESCRIPTION
Drive TransFilter
Harmonic
Filtering Drive Isolation Transformers are Ultra-High
Efficiency three-phase drive isolation transformers that
have been specifically designed to mitigate the power
quality problems associated with three-phase, six and twelve
pulse Adjustable Speed Drives (ASD). |

|
|
|
Drive TransFilter
provide a
significant power quality improvement by canceling positive and
negative sequence harmonic currents on a common distribution system
bus and/or within the secondary windings of a multiple output
transformer.
In
addition, the device will deliver all the benefits normally provided
by conventional drive isolation transformers including electrical
isolation of the drive, fault current reduction at the drive,
absorption of phase-ground voltage shifts, associated with the
inverter operation, and a 100% increase in allowable drive loading. |
|
|
TECHNICAL SPECIFICATION
Drive TransFilter
Harmonic Filtering Transformers are proprietary three-phase, four-wire, copper-wound, common-core isolation transformers.
Drive TransFilter
 |
|
Drive
Auto TransFilter
-
Phase Shifting Line Reactors
|
|
DESCRIPTION
Drive Auto TransFilter
Harmonic Mitigating
Phase Shifted Line Reactors provide a significant power quality
improvement by canceling positive and negative sequence harmonic
currents on a common distribution system bus and/or within the
secondary windings of a multiple output reactor. |
 |
|
In addition, the device will deliver all the
benefits normally provided by conventional drive reactors including
fault current reduction at the drive and a 100% increase in
allowable drive loading. |
|
|
TECHNICAL SPECIFICATION
Drive Auto TransFilter
Harmonic
Filtering Reactors are proprietary three-phase, four-wire,
copper-wound, common-core reactors.
Drive Auto TransFilter
 |
|
Power
TransFilter
- Harmonic Mitigating Transformer
|
|
DESCRIPTION
Power TransFilter
Harmonic
Mitigating Transformers are Ultra-High Efficiency three-phase,
medium voltage class power transformers that have been specially
designed to mitigate the power quality problems associated with
non-linear, load generated harmonic currents in three-phase
electrical distribution systems. |
 |
|
K-Rated or de-rated Transformers are only
intended to survive in a harmonic environment. By contrast,
Power TransFilters
will cancel zero
sequence harmonic fluxes within the three-phase magnetic core. In
addition, positive and negative sequence harmonic currents will
cancel on their primary bus or within their dual output secondary
windings. |
|
|
TECHNICAL SPECIFICATION
Power TransFilter
Harmonic
Filtering Transformers are proprietary three-phase, four-wire,
copper-wound, common-core isolation transformers. Type DV
transformers, with less than 0.9% zero sequence impedance and less
than 0.3% reactance, provide a parallel (shunt) paths, with
ultra-low zero sequence impedance, for all single-phase
load-generated zero sequence harmonic currents.
Power TransFilter
Harmonic
Filtering Transformers are available in cast-coil designs.
Power TransFilter
 |
|
Conventional and Custom
Products |
|
DESCRIPTION
PQI can
supply single-phase, three-phase conventional, K-Rated and custom
dry-type transformers, and reactors, in any rating up to and
including 8MVA (3) and 35kV, upon request. |
|
|
TECHNICAL SPECIFICATION
Power Quality International, Inc. is able to
design and supply any standard or custom dry-type transformer or
reactor. We are also able to manufacture electromagnetic devices to
our customers proprietary design.
|
|
|